The following is a list of parameters and notation used in this report.


Laser and Modulator parameters
$ M$ 256, 64, 2 PPM order
$ T_s$ $ 3.125 \times 10^{-8}$ Width of the PPM slot required by laser, in seconds
$ T_d$ $ 4.32 \times 10^{-4}$ Dead time between PPM symbols required by laser, in seconds
$ \alpha_{er}$ $ 10^6$ Modulation extinction ratio
Received light
$ \bar n_s$ 100 Average number of signal photons incident on the photodetector, per pulse
$ \bar n_b$ 0.001 - 10,000 Average number of background photons incident on the photodetector, per slot
APD detector parameters
$ \eta$ 38% Quantum efficiency
$ k_{\mbox{\small \em eff}}$ 0.007 Ionization ratio
$ T$ 300 Noise temperature, in Kelvin
$ G$ 50-200 Gain
$ R$ 179700 Load resistance implied by transimpedance model, $ 5.75\times 10^{12} \times T_s$, in Ohms
$ B$ $ 1\over 2T_s$ Noise equivalent one-sided bandwidth, in Hz.
$ I_b$ $ 4\times 10^{-14}$ Bulk leakage current, in Amperes
$ I_s$ $ 2\times 10^{-9}$ Surface leakage current, in Amperes
Constants
$ \kappa$ $ 1.6\times 10^{-19}$ Boltzmann's constant, in Joules/Kelvin
$ e_-$ $ 1.38\times 10^{-23}$ Electron charge, in Coulombs
Error probabilities
$ p$   Probability of correct uncoded PPM detection
$ q$   Probability uncoded PPM symbol $ i$ is detected as symbol $ j$, $ j \ne i$.